Furnace installation and replacement in Toronto runs $4,500–$7,500 for a high-efficiency gas furnace, installed, with removal of the old unit and any permit the job needs in the written quote. In the city's older semis and row houses the price is decided less by the furnace than by where the vent pipes can exit, what happens to the chimney, and whether the retrofit ducts can carry the airflow. ZK Mechanical measures all three before quoting, and the quote visit is free.
What changes a furnace replacement in a Toronto house
Every new gas furnace sold in Canada must be at least 95% AFUE, which means a condensing unit that vents through plastic pipe instead of the chimney. In a suburb those pipes go out the nearest side wall; on a Toronto semi one side is a party wall and the other faces the neighbour's wall across a narrow passage. CSA B149.1 and the manufacturer set clearances from windows, doors, gas regulators and air intakes, so the termination often has to move to the rear wall or go up through the roof, using the old chimney as a chase. That route sets the pipe length, and pipe length can decide which furnace model is allowed, so we walk it before quoting.
The chimney is the second question. Once the furnace leaves it, a gas water heater is left venting alone into a brick flue that is now too big and too cold for it, and its exhaust can spill back into the basement. The fix is a liner sized to the water heater, or a power-vent or tankless unit that does not use the chimney, and it belongs in the furnace quote from the start; chimney liners when replacing a furnace explains the choice. In a semi the chimney often sits on the party wall with a separate flue for each house, so we confirm which flue is yours before anything goes down it.
Size comes from a heat-loss calculation, not from the nameplate on the old furnace. A semi or row house shares one or two walls with heated neighbours, so it loses less heat than a detached house of the same floor area, and the right furnace is often smaller than the one coming out. Ducts matter as much: forced air in these houses was usually retrofitted, with small returns, and a furnace too large for them trips its limit switch and wears out early. A two-stage or modulating furnace that runs on low fire most of the winter suits small ducts and a low dug-out basement, where we also measure the height available for cabinet, coil and plenum.
The City of Toronto lists replacing a furnace or boiler in a house among the work that does not require a building permit; a permit comes back in when the heating system is installed or modified, such as new ductwork, and then we file it with Toronto Building as the contractor. The gas connection is made by a TSSA-licensed technician in every case, and do I need a permit to replace my furnace in Toronto sets out the rule. If the house heats with radiators and has no ducts, a furnace is rarely the answer, and boiler repair and installation in Toronto is the page to read. Ontario's Home Renovation Savings Program is aimed at heat pumps, insulation and windows more than at gas furnaces, so we state in writing what it will pay on your job. See the furnace installation service page for the install day, the Toronto service area page for where we work, and request a free quote to have the house measured.
Why ZK Mechanical for furnace installation & replacement in Toronto
- Vent route walked and measured first: side wall, rear wall or through the roof by way of the old chimney
- Orphaned water heater dealt with in the same quote, with a liner, power-vent or tankless option priced
- Heat-loss calculation for attached houses, which usually need less furnace than the old nameplate suggests
- Two-stage and modulating furnaces matched to small retrofit ducts
- No Toronto building permit needed for a straight furnace swap in a house; where duct changes need one, we file it and book the inspection
- TSSA-licensed gas technicians; gas line pressure-tested and the furnace test-fired before we leave
- Old furnace removed and disposed of; financing through lending partners with no prepayment penalty
Licensed technicians, Toronto dispatch, no overtime charges.
Furnace Installation & Replacement in Toronto — FAQs
How much does furnace installation cost in Toronto?
A high-efficiency gas furnace is $4,500–$7,500 installed. A premium-tier model adds $500–$1,500. Replacing the furnace and air conditioner together typically runs $7,500–$11,500. A straight replacement in a house needs no Toronto building permit; where the job modifies the heating system and does need one, municipal fees are typically $100–$300 and sit inside the quote, as does removal of the old furnace. A chimney liner, a roof vent route or duct changes are itemized separately so you can see what the house added to the price.
Where will the vent pipes go on a semi-detached house?
Wherever the code clearances and the manufacturer's maximum pipe length both allow. The first choice is the open side wall, if windows, the gas meter and the neighbour's openings leave a legal spot. Second is the rear wall, which means a longer run across the basement ceiling. Third is straight up through the roof inside the old chimney. We mark the termination on the outside wall at the quote visit so you can see it.
How long will the house be without heat?
One working day for a straightforward replacement: the old furnace comes out in the morning and the new one is firing by evening. A chimney liner, a roof vent or plenum rebuilding in a low basement can add a second day, and in winter we schedule that extra work so the house has heat overnight. If the old furnace has already failed, tell us; a no-heat house is scheduled ahead of a planned swap.
Should I replace the air conditioner at the same time?
If the AC is past 12 years, usually yes. The two share the blower and the plenum, and one visit instead of two typically saves about a thousand dollars, with the pair running $7,500–$11,500. If the AC is under 10 years old, keep it and we set the new furnace up to work with it. On a narrow lot, a combined job is also the moment to move a badly placed outdoor unit.
Would a heat pump make more sense than a new furnace?
Sometimes. A hybrid system pairs a heat pump with a gas furnace, so the heat pump carries mild weather and the furnace takes the coldest days, and heat pumps are the equipment Ontario's current rebate program is built around. On a west-side lot the practical limits are a spot for the outdoor unit that respects the neighbours' windows, and room in the electrical panel. We check both and price furnace-only and hybrid side by side.