ZK Mechanical
Request a free quote
What do you need? Pick everything that applies

Free quote, in writing, no obligation. Or just call (647) 801-1252, 24/7.

Home / Glossary / Secondary heat exchanger

Furnace parts · HVAC glossary

What Is a Secondary Heat Exchanger?

A secondary heat exchanger is the second coil in a condensing gas furnace, usually stainless steel, that pulls extra heat out of the flue gases until their water vapour condenses, which is why these furnaces vent through plastic pipe and need a drain.

Reviewed by Zobir, licensed technician

High-efficiency furnace beside a gas water heater and humidifier

In short

A secondary heat exchanger is the extra coil that makes a furnace high-efficiency. It cools the exhaust until the water vapour in it condenses, recovering heat a mid-efficiency furnace sends up the chimney. Nearly every gas furnace installed in the GTA since about 2010 has one. When it plugs or leaks, expect pressure-switch faults, water under the furnace or weak airflow.

A secondary heat exchanger is what separates a 95% AFUE furnace from the 80% furnace it replaced. The older furnace sent its exhaust out hot; the newer one runs that exhaust through a second coil first and keeps most of the heat that used to be lost.

What a secondary heat exchanger does in a condensing furnace

The secondary heat exchanger takes the flue gases after they leave the primary heat exchanger and pulls more heat out of them. It looks like a small car radiator: rows of narrow tubes with fins, sitting in the air stream near the blower. Return air crosses it first and cools the exhaust inside below its dew point, so the water vapour in the exhaust turns to liquid. That change of state releases heat, and it is where the extra efficiency comes from.

Two things follow. The exhaust leaves cool enough for certified plastic vent pipe instead of a metal chimney, and the furnace makes water that drains away through a condensate trap. The condensate is mildly acidic, which is why the coil is normally stainless steel.

Why almost every GTA furnace has one

Condensing efficiency has been the federal minimum for new residential gas furnaces in Canada for well over a decade, and the minimum today is 95% AFUE. A gas furnace installed in a Burlington, Milton or Brampton house since about 2010 is almost certainly a condensing model. The exceptions are mid-efficiency furnaces still venting into a chimney or metal vent, mostly in 1970s to 1990s homes that have not had a replacement yet.

How a secondary heat exchanger fails

A secondary heat exchanger fails by plugging or by leaking, and it can plug on either side. On the flue side, corrosion scale and debris narrow the tubes until the inducer cannot pull enough draft. On the air side, the fins catch whatever dust gets past the filter, because the coil sits in the air stream like a second filter.

  • Repeated pressure switch faults with a clear vent and a clean trap.
  • Water under or inside the furnace cabinet, from a leaking coil or collector box.
  • Rust streaks or white mineral tracks down the inside of the cabinet.
  • Weak airflow and a high temperature rise even with a new filter.

Running without a filter, or with one that does not fit its slot, is the usual cause of air-side plugging. Flue-side plugging tends to follow years of poor combustion or condensate that never drained properly.

What it costs: usually a warranty part with heavy labour

There is no flat price for a secondary heat exchanger, because the labour depends on the model. Reaching it means removing the blower, the inducer assembly and sometimes the primary exchanger. Manufacturers commonly cover heat exchangers under a longer warranty than other parts, so the part may cost little while the labour takes much of a day. A written quote after inspection is the only honest number.

  • Air-side dirt only: the coil can often be cleaned in place, which is a far smaller job.
  • Leaking or flue-side plugged, furnace under about 12 years old, part under warranty: replacement is usually worth doing.
  • Leaking or plugged on a furnace past 12 to 15 years: weigh the labour against a new furnace at $4,500–$7,500 installed.

The repair versus replacement cost guide lays out that comparison. For a diagnosis backed by photos and combustion readings, book furnace repair at (647) 801-1252 or ask for a written quote.

Questions people ask about Secondary heat exchanger

Does a mid-efficiency furnace have a secondary heat exchanger?

No. A mid-efficiency furnace, around 80% AFUE, has a primary heat exchanger only. Its exhaust stays hot enough to rise up a metal vent or lined chimney, and by design it makes no condensate. If your furnace vents through white or grey plastic pipe out the side wall and has a drain hose, it is a condensing furnace and has a secondary.

Can a secondary heat exchanger be cleaned instead of replaced?

Often, when the dirt is on the air side. With the blower removed, the fins can be brushed and vacuumed, which restores airflow. Flue-side blockage is harder: some manufacturers publish a flushing procedure and others call for replacement. A coil that is leaking condensate into the cabinet cannot be cleaned back to health and has to be replaced.

Is a leaking secondary heat exchanger dangerous?

Treat it as a problem to fix promptly. Leaking condensate rusts the cabinet and can drip onto the blower and control board. A coil corroded through between the flue side and the air side is a breached heat exchanger, and a licensed technician who finds that must shut the furnace off and tag it. Have a leak inspected before running the furnace all winter.

Related

Plain answers. Licensed work.