Why does my gas fireplace smell when it is on?

Reviewed by Zobir, licensed technician

Living room with a fireplace

Quick answer

A gas fireplace that smells when it is on is usually burning off dust at the first fire of the season, or curing paint if the unit is new; both fade within a few hours of burning. A rotten-egg smell at start-up means unburnt gas: shut it off and call. An exhaust smell, soot or headaches mean a venting or gasket fault with carbon monoxide risk: stop using it.

The reason your gas fireplace smells when it is on depends on what the smell is like and when it shows up. A hot, dusty odour in October is housekeeping. Sulphur at ignition is fuel, and a sharp exhaust smell is combustion gas escaping the firebox. Sort it into one of those three and you know whether to open a window, book a service or shut it off.

Normal smells: dust burn-off and paint curing on a new unit

A fireplace that sat idle since April collects dust, pet hair and cobwebs on the top of the firebox, around the burner and on the fan. The first fire of the season scorches it off, and the smell is like a hair dryer or a toaster that has not been used for a while. It should fade within the first few hours of burning and be gone after a fire or two.

A new fireplace, or one with new logs or a repainted firebox, smells for a different reason. The high-temperature paint and the binders in the log set cure with heat, giving off a chemical, slightly sweet odour and sometimes a light haze. Manufacturers call for an initial burn of several hours with the windows open. A white film on the inside of the glass after that burn is normal and comes off with fireplace glass cleaner once the glass is cold.

Things in the room can smell too. A sealed direct-vent fireplace does not burn room air, but its hot surfaces bake whatever settles on them: fumes from fresh paint, new carpet, scented candles, air fresheners, even a television mounted too close above. If the smell started after a renovation, that is the first suspect.

A gas (rotten-egg) smell at start-up: delayed ignition or a leak

The rotten-egg odour is the odourant added to natural gas and propane so that a leak gets noticed. A brief whiff followed by a soft whump as the burner lights is delayed ignition: gas flows for a moment before the flame carries across the burner, because the ports near the pilot are blocked with dust or a log is sitting over them. It gets worse with time, and a hard enough ignition can crack the glass.

A sulphur smell that lingers while the fireplace runs, or is there when it is off, is a leak at the valve, the flex connector or a fitting under the firebox. Turn the fireplace off, do not relight it, leave the room and follow the steps in what to do if you smell gas, which start with calling Enbridge Gas or 911 from outside. A licensed gas technician then has to leak-test the unit before it burns again.

An exhaust smell or soot: glass gasket, vent or log placement, with CO risk

Exhaust in the room means the sealed firebox is no longer sealed, or the fire is burning badly, or both. On a direct-vent fireplace the usual causes are these:

  • A failed or flattened glass gasket, or a glass frame that was not latched evenly after cleaning. Combustion gas leaks around the edge and often leaves a brown or black streak on the surround.
  • A vent fault: a cap blocked by a nest, snow or ice, a pipe joint that has separated inside the wall or chase, or a termination crowded by a deck or soffit added later.
  • Misplaced logs. Each log set has pins or notches and a placement diagram in the manual. A log shifted into the flame path causes impingement: the flame cools on the ceramic, turns orange and makes soot and carbon monoxide.
  • Ember material piled over the burner ports, or more of it than the manual allows.

Soot is the visible warning. Black deposits on the logs, on the glass or on the outside vent cap mean incomplete combustion, and incomplete combustion makes carbon monoxide. Stop using the fireplace until it has been cleaned and tested, and confirm the CO alarm on that floor is working and in date.

Fireplace smell guide: can wait, book soon, or shut it off

  • Hot dust at the first fires of the season, weaker each time: can wait. Vacuum the lower compartment with the gas off and the unit cold.
  • Paint or chemical smell on a new unit, fading over the first several hours of burning: normal. Ventilate the room.
  • A brief gas whiff and a thump at ignition: book a service visit soon, and stop using it if the thump gets louder.
  • A constant sulphur smell, on or off: shut it off, leave and call the utility.
  • Exhaust smell, soot, stinging eyes, a headache or a CO alarm: shut it off, get to fresh air and call 911 if anyone feels unwell.

What a technician does about a fireplace smell

A service visit for a smell is a cleaning plus a set of measurements. The technician removes the glass and logs, vacuums the burner and pilot, sets the logs against the manual's diagram, inspects the gasket and vent, leak-tests the gas train, then relights and measures carbon monoxide in the room and along the glass edge. The diagnostic visit runs $90–$150, credited toward the repair if parts are needed; gaskets and log sets are specific to the make and are quoted in writing.

ZK Mechanical services gas fireplaces in Burlington, Oakville, Hamilton and Mississauga and replaces units that are no longer safe to run. See gas fireplace installation for what a new direct-vent unit involves and whether a gas fireplace needs a permit. To book, phone (647) 801-1252 or use the contact page.